Valve actuators SVM 05.1 - 07.5/SVMR 05.1 - 07.5 parallel, military ship building (navy)
Cut-away drawing
application/pdf698.6 KB
Downloads
Valve actuators SVM 05.1 - 07.5/SVMR 05.1 - 07.5 Profibus DP, military ship building (navy)
Cut-away drawing
application/pdf645.5 KB
Downloads
Multi-turn Actuators PF-M25 – PF-M100 PROFOX
Cut-away drawing
application/pdf1.1 MB
Downloads
Multi-turn Actuators PF-M25X – PF-M100X PROFOX
Cut-away drawing
application/pdf1.1 MB
Downloads
Part-turn Actuators PF-Q80 – PF-Q600 PROFOX
Cut-away drawing
application/pdf1 MB
Downloads
Multi-turn Actuators PF-Q80X – PF-Q600X PROFOX
Cut-away drawing
application/pdf1 MB
Downloads
Multi-turn actuators SA 25.1-UW - 30.1-UW for continuous underwater use
Cut-away drawing
application/pdf112.7 KB
Downloads
Multi-turn actuators SA 25.1 - 48.1 NORM
Cut-away drawing
application/pdf578.7 KB
Downloads
Multi-turn actuators SA 07.2 - 16.2 NORM
Cut-away drawing
application/pdf4.8 MB
Downloads
Multi-turn actuators SA 07.2 - 16.2 AC 01.2
Cut-away drawing
application/pdf1.5 MB
Downloads
Multi-turn actuators SA(V) 07.2-UW - 16.2-UW for continuous underwater use
Cut-away drawing
application/pdf100 KB
Downloads
A1: AUMATIC AC 01.2 position feedback signal 0/4 - 20 mA (potentiometer in actuator), basic version, reversing contactors OPEN, STOP, CLOSE, EMERGENCY (24 V DC), 6 programmable output contacts, AUMA power class A1 - A3
Wiring diagram
application/pdf189.3 KB
Downloads
A1N: AUMATIC AC 01.2 position/torque feedback signal 0/4 - 20 mA (MWG in actuator), reversing contactors OPEN, STOP, CLOSE, EMERGENCY (24 V DC), 6 programmable output contacts, AUMA power class A1 - A3
Wiring diagram
application/pdf192.3 KB
Downloads
A2: AUMATIC AC 01.2 positioner and postition feedback signal 0/4 - 20 mA (potentiometer in actuator), reversing contactors OPEN, STOP, CLOSE, EMERGENCY, MODE (24 V DC), 6 programmable output contacts, AUMA power class A1 - A3
Wiring diagram
application/pdf264.6 KB
Downloads
A2DP: AUMATIC AC 01.2 position feedback (potentiometer in actuator), basic version, reversing contactors, Profibus, AUMA power class A1 - A3
Wiring diagram
application/pdf211 KB
Downloads
A2ENIP: AUMATIC AC 01.2 position feedback (potentiometer in actuator), basic version, reversing contactors, Ethernet/IP, AUMA power class A3 - A3
Wiring diagram
application/pdf211.1 KB
Downloads
A2FF: AUMATIC AC 01.2 position feedback (potentiometer in actuator), basic version, Reversing contactors, Foundation Fieldbus FF, AUMA power classes A1 – A3
Wiring diagram
application/pdf212.7 KB
Downloads
A2HRT: AUMATIC AC 01.2 position feedback (potentiometer in actuator), basic version, Reversing contactors, HART actuatorAUMA power classes A1 – A3
Wiring diagram
application/pdf291.2 KB
Downloads
A2HRTCO: AUMATIC AC 01.2 position feedback (potentiometer in actuator), basic version, Reversing contactors, HART Current Output, AUMA power classes A1 – A3
Wiring diagram
application/pdf240.2 KB
Downloads
A2MB: AUMATIC AC 01.2 position feedback (potentiometer in actuator), basic version, reversing contactors, Modbus RTU, AUMA power class A1 - A3
Wiring diagram
application/pdf175.7 KB
Downloads
A2MBTCP: AUMATIC AC 01.2 position feedback (potentiometer in actuator), basic version, Reversing contactors, Modbus TCP/IP, AUMA power classes A1 – A3
Wiring diagram
application/pdf177.1 KB
Downloads
A2N: AUMATIC AC 01.2 positioner and position/torque feedback signal 0/4 - 20 mA (MWG in actuator), , reversing contactors OPEN, STOP, CLOSE, EMERGENCY, MODE (24 V DC), 6 programmable output contacts, AUMA power class A1 - A3
Wiring diagram
application/pdf229.7 KB
Downloads
A2NDP: AUMATIC AC 01.2 position/torque feedback (MWG in actuator), reversing contactors, Profibus, AUMA power class A1 - A3
Wiring diagram
application/pdf229.6 KB
Downloads
A2NENIP: AUMATIC AC 01.2, position/torque feedback (MWG in actuator, reversing contactors, Ethernet/IP, AUMA power class A1 - A 3
Wiring diagram
application/pdf225.6 KB
Downloads
A2NFF: AUMATIC AC 01.2 position/torque feedback (MWG in actuator), Reversing contactors, Foundation Fieldbus FF, AUMA power classes A1 – A3
Wiring diagram
application/pdf192.8 KB
Downloads
A2NHRT: AUMATIC AC 01.2 position/torque feedback (MWG in actuator), Reversing contactors, HART actuator, AUMA power classes A1 – A3
Wiring diagram
application/pdf228.5 KB
Downloads
A2NHRTCO: AUMATIC AC 01.2 position/torque feedback (MWG in actuator), Reversing contactors, HART Current Output, AUMA power classes A1 – A3
Wiring diagram
application/pdf226.3 KB
Downloads
A2NMB: AUMATIC AC 01.2 position/torque feedback (MWG in actuator), reversing contactors, Modbus RTU, AUMA power class A1 - A3
Wiring diagram
application/pdf159.7 KB
Downloads
A2MBTCP: AUMATIC AC 01.2 position/torque feedback (MWG in actuator), Reversing contactors, Modbus TCP/IP, AUMA power classes A1 – A3
Wiring diagram
application/pdf161.5 KB
Downloads
A3ENIP: AUATIC AC 01.2 postition feedback (potentiometer in actuator), Thyristors, EtherNet/IP, AUMA power class B1/B2
Wiring diagram
application/pdf199.2 KB
Downloads
A3ENIP: AUATIC AC 01.2 postition feedback (potentiometer in actuator), Thyristors, EtherNet/IP, AUMA power class B3
Wiring diagram
application/pdf195.1 KB
Downloads
A3FF: AUMATIC AC 01.2 position feedback (potentiometer in actuator), Thyristors, Foundation Fieldbus FF, AUMA power class B1/B2
Wiring diagram
application/pdf184.2 KB
Downloads
A3FF: AUMATIC AC 01.2 position feedback (potentiometer in actuator), Thyristors, Foundation Fieldbus FF, AUMA power class B3
Wiring diagram
application/pdf166.1 KB
Downloads
A3HRT: AUMATIC AC 01.2 position feedback (potentiometer in actuator), Thyristors, HART actuator, AUMA power class B1/B2
Wiring diagram
application/pdf203.6 KB
Downloads
A3NMBTCP: AUMATIC AC 01.2 position/torque feedback (MWG in actuator), Thyristors, Modbus TCP/IP, AUMA power class B1/B2
Wiring diagram
application/pdf193.2 KB
Downloads
A3NMBTCP: AUMATIC AC 01.2 position/torque feedback (MWG in actuator), Thyristors, Modbus TCP/IP, AUMA power class B3
Wiring diagram
application/pdf189.9 KB
Downloads
A4DP: AUMATIC AC 01.2 positioner and position feedback signal 0/4 - 20 mA (potentiometer in actuator),basic version, reversing contactors MODE, CLOSE, OPEN, STOP, EMERGENCY, I/O (24 V DC), Profibus DP, AUMA power class A1 - A3
Wiring diagram
application/pdf220.6 KB
Downloads
A4ENIP: AUMATIC AC 01.2 positioner and position feedback signal 0/4 - 20 mA (potentiometer in actuator), basic version, reversing contactors MODE, CLOSE, OPEN, STOP, EMERGENCY, I/O (24 V DC), 6 programmable output contacts Ethernet/IP, AUMA power class
Wiring diagram
application/pdf229.4 KB
Downloads
A4FF: AUMATIC AC 01.2 positioner and position feedback signal 0/4 – 20 mA (potentiometer in actuator), basic version, Reversing contactors MODE, CLOSE, OPEN, STOP, EMERGENCY, I/O (24V DC), 6 programmable output contacts, FF, AUMA power classes A1-A3
Wiring diagram
application/pdf215.2 KB
Downloads
A4HRT: AUMATIC AC 01.2 positioner and position feedback signal 0/4-20mA (potentiometer within actuator), basic version, Reversing contactors MODE, CLOSE, OPEN, STOP, EMERGENCY, I/O (24V DC), 6 programmable output contacts, HART AUMA power classes A1 – A3
Wiring diagram
application/pdf231.8 KB
Downloads
A4HRTCO: AUMATIC AC 01.2 positioner and position feedback signal 0/4-20mA (potentiometer in actuator), basic version, Reversing contactors MODE, CLOSE, OPEN, STOP, EMERGENCY, I/O (24V DC), 6 programmable output contacts, HART, AUMA power classes A1-A3
Wiring diagram
application/pdf269.1 KB
Downloads
A4MB: AUMATIC AC 01.2 positioner and position feedback signal 0/4 - 20 mA (potentiometer in actuator), basic version, reversing contactors MODE, CLOSE, OPEN, STOP, EMERGENCY, I/O (24 V DC), 6programmable output contacts, Modbus RTU, power class A1 - A3
Wiring diagram
application/pdf218.3 KB
Downloads
A4MBTCP: AUMATIC AC 01.2 positioner and position feedback signal 0/4–20 mA (potentiometer in actuator), basic version, Reversing contactors MODE, CLOSE, OPEN, STOP, EMERGENCY, I/O (24V DC), 6 programmable output contacts, Modbus RTU, power classes A1-A3
Wiring diagram
application/pdf213.3 KB
Downloads
A4N: AUMATIC AC 01.2 process controller and position/torque feedback signal 0/4 - 20 mA (MWG in actuator), thyristors CLOSE, OPEN, STOP, EMERGENCY, MODE (24 V DC), 6 programmable output contacts, AUMA power class B1/B2
Wiring diagram
application/pdf240.7 KB
Downloads
A4NDP: AUMATIC AC 01.2 positioner and position/torque feedback signal 0/4 - 20 mA (MWG in actuator), reversing contactors MODE, CLOSE, OPEN, STOP, EMERGENCY, I/O (24 V DC), 6 programmable output contacts, Profibus DP, AUMA power class A1 - A3