Evropa

Deutschland

Deutsch

United Kingdom

English

Česko

Čeština

España

Español

Suomi

Suomi

France

Français

Magyarország

Magyar

Italia

Italiano

Nederland

Nederlands

Polska

Polski

Россия

Русский

Sverige

Svenska

Asie a Pacifik

日本

日本語

Türkiye

Türkçe

中国

中文

India

English

Vyhledávání

Vyberte si vaše filtry

Typ dokumentu

Stažení

Dokumenty

Zde naleznete veškeré vytištěné informace k naším produktům.

Všechny filtry

Výsledky 315

Všechny filtry

Vybrané filtry

Smazat všechny filtry

Výsledky vyhledávání pro "The route to AUMA Servopohony"

Specification

Multi-turn actuators SA 07.2 - 16.2 actuator controls AUMA MATIC AM 01.1

Specification
Stáhnout
application/vnd.openxmlformats-officedocument.wordprocessingml.document 43.7 KB

Part-turn actuators SG 03.3 - 05.3, Actuator controls AUMA MATIC AM 01.1

Specification
Stáhnout
application/msword 69.5 KB

Technical Data Catalogue

Technical documentation 2024 - Electric actuators for valve automation in the oil & gas industry

Technical Data Catalogue
Stáhnout
application/pdf 17.5 MB

Technical documentation 2024 - Electric multi-turn actuators for valve automation in the oil & gas industry with high torque requirements

Technical Data Catalogue
Stáhnout
application/pdf 6.9 MB

Technical data

Actuators, Technical data Ambient temperatures/lubricant in the gear housing

Technical data
Stáhnout
application/pdf 53 KB

Gearboxes, Output drives, Technical data Ambient temperatures/lubricant in the gear housing

Technical data
Stáhnout
application/pdf 29.9 KB

Technical description

Conversion of MTTF values for high numbers of starts and to MCTF values

Technical description
Stáhnout
application/pdf 41.3 KB

Name plates AUMA devices

Technical description
Stáhnout
application/pdf 96.8 KB

Wiring diagram

A1: AUMATIC AC 01.2 position feedback signal 0/4 - 20 mA (potentiometer in actuator), basic version, reversing contactors OPEN, STOP, CLOSE, EMERGENCY (24 V DC), 6 programmable output contacts, AUMA power class A1 - A3

Wiring diagram
Stáhnout
application/pdf 189.3 KB

A1: AUMATIC ACExC 01.2 position feedback signal 0/4 - 20 mA (potentiometer in actuator),basic version, reversing contactors CLOSE, OPEN, STOP, EMERGENCY (24 V DC), 6 programmable output contacts, AUMA power class A1 - A3

Wiring diagram
Stáhnout
application/pdf 357.3 KB

A1N: AUMATIC AC 01.2 position/torque feedback signal 0/4 - 20 mA (MWG in actuator), reversing contactors OPEN, STOP, CLOSE, EMERGENCY (24 V DC), 6 programmable output contacts, AUMA power class A1 - A3

Wiring diagram
Stáhnout
application/pdf 192.3 KB

A1N: AUMATIC ACExC 01.2 position/torque feedback signal 0/4 - 20 mA (MWG in actuator), reversing contactors CLOSE, OPEN, STOP, EMERGENCY (24 V DC), 6 programmable output contacts, AUMA power class A1 - A3

Wiring diagram
Stáhnout
application/pdf 82 KB

A2: AUMATIC AC 01.2 positioner and postition feedback signal 0/4 - 20 mA (potentiometer in actuator), reversing contactors OPEN, STOP, CLOSE, EMERGENCY, MODE (24 V DC), 6 programmable output contacts, AUMA power class A1 - A3

Wiring diagram
Stáhnout
application/pdf 264.6 KB

A2: AUMATIC ACExC 01.2 positioner and position feedback signal 0/4 - 20 mA (potentiometer in actuator), reversing contactors MODE, CLOSE, OPEN, STOP, EMERGENCY (24 V DC), setpoint (0/4 - 20 mA), 6 programmable output contacts, AUMA power class A1 -

Wiring diagram
Stáhnout
application/pdf 142.9 KB

A2DP: AUMATIC AC 01.2 position feedback (potentiometer in actuator), basic version, reversing contactors, Profibus, AUMA power class A1 - A3

Wiring diagram
Stáhnout
application/pdf 211 KB

A2DP: AUMATIC ACExC 01.2 position feedback (potentiometer in actuator), basic version, reversing contactors, Profibus, AUMA power class A1 - A3

Wiring diagram
Stáhnout
application/pdf 133.5 KB

A2ENIP: AUMATIC AC 01.2 position feedback (potentiometer in actuator), basic version, reversing contactors, Ethernet/IP, AUMA power class A3 - A3

Wiring diagram
Stáhnout
application/pdf 211.1 KB

A2ENIP: AUMATIC ACExC 01.2 position feedback (potentiometer in actuator), basic version, reversing contactors, EtherNet/IP, AUMA power class A1 - A3

Wiring diagram
Stáhnout
application/pdf 132.9 KB

A2FF: AUMATIC AC 01.2 position feedback (potentiometer in actuator), basic version, Reversing contactors, Foundation Fieldbus FF, AUMA power classes A1 – A3

Wiring diagram
Stáhnout
application/pdf 212.7 KB

A2FF: AUMATIC ACExC 01.2 position feedback (potentiometer in actuator), basic version, reversing contactors, Foundation Fieldbus FF, AUMA power class A1 - A3

Wiring diagram
Stáhnout
application/pdf 128.9 KB

A2HRT: AUMATIC ACExC 01.2 position feedback (potentiometer in actuator), reversing contactors, HART actuator, AUMA power class A1 - A3

Wiring diagram
Stáhnout
application/pdf 134.9 KB

A2HRTCO: AUMATIC AC 01.2 position feedback (potentiometer in actuator), basic version, Reversing contactors, HART Current Output, AUMA power classes A1 – A3

Wiring diagram
Stáhnout
application/pdf 240.2 KB

A2HRTCO: AUMATIC ACExC 01.2 position feedback (potentiometer in actuator), basic version, reversing contactors, HART current output, AUMA power class A1 - A3

Wiring diagram
Stáhnout
application/pdf 127.6 KB

A2MB: AUMATIC AC 01.2 position feedback (potentiometer in actuator), basic version, reversing contactors, Modbus RTU, AUMA power class A1 - A3

Wiring diagram
Stáhnout
application/pdf 175.7 KB

1-24 z 315 Výsledky vyhledávání